Installing an accessory fuse box: Difference between revisions
No edit summary |
|||
| Line 1: | Line 1: | ||
[[Category:Electrical & Lighting]] | [[Category:Electrical & Lighting]] | ||
This is currently not visible to the general public, so make as many notations as you'd like (Ryan will have to copy and PM). My comments or questions are in '''''bold italics''''' | This is currently not visible to the general public, so make as many notations as you'd like (Ryan will have to copy and PM). My comments or questions are in '''''bold italics''''' | ||
| Line 20: | Line 14: | ||
====What kinds of boxes are there?==== | ====What kinds of boxes are there?==== | ||
There are a few different types of fuse/ | There are a few different types of fuse blocks/panels. Some distribution blocks treat each attachment point as a separate entity, requiring that power be sent directly from the battery to each connection point on the block (individual circuits) like the [http://www.centechwire.com/catalog/panels/ap1.shtml Centech AP1]. In this case you can daisy chain (make very short connections) the power wires from one connection to the next, instead of running a wire from the battery for each. This article does not cover this type, as it's more difficult to do. | ||
The [http://easternbeaver.com/Main/Products/Fuseboxes/FB-4/fb-4.html Eastern Beaver FB-4] also works this way, but it comes in a kit with everything wired for you. This is the easiest reasonably-priced box to use if you haven't done this sort of thing before. | The [http://easternbeaver.com/Main/Products/Fuseboxes/FB-4/fb-4.html Eastern Beaver FB-4] also works this way, but it comes in a kit with everything wired for you. This is the easiest reasonably-priced box to use if you haven't done this sort of thing before. | ||
| Line 65: | Line 57: | ||
*[[Waterproofing your electrical connections|Dielectric grease]] - again optional, but a very good idea. | *[[Waterproofing your electrical connections|Dielectric grease]] - again optional, but a very good idea. | ||
====Finding a mounting location==== | |||
The first thing to tackle is finding a place for your new fuse box. This does not mean that you should mount it yet. As always, try to test everything before mounting, in the interest of saving time if something gets hooked up wrong. | |||
====Hooking it up==== | ====Hooking it up==== | ||
| Line 70: | Line 68: | ||
For the purposes of this article, we will be following the installation of the Bussman 15600. If you are using one of the Eastern Beaver units, hook the relay up the same, then [http://easternbeaver.com/Main/Products/Fuseboxes/FB-4/Install/install.html follow their directions]. Mounting will be virtually the same as with the Bussman. | For the purposes of this article, we will be following the installation of the Bussman 15600. If you are using one of the Eastern Beaver units, hook the relay up the same, then [http://easternbeaver.com/Main/Products/Fuseboxes/FB-4/Install/install.html follow their directions]. Mounting will be virtually the same as with the Bussman. | ||
'''''Does it need to be spelled out where to route everything?''''' | '''''Does it need to be spelled out where to route everything?''''' | ||
| Line 183: | Line 178: | ||
[[image:buss-10.jpg|100px]] | [[image:buss-10.jpg|100px]] | ||
Make sure all the connections are connected, mounting points tightened, and you're done. Our home mechanic says, "My Bussman setup cost me about $15, including the relay, wiring and end connections. I've been very happy with it. I've had no averse weather issues with its 'open' design. The two factors that have helped make that occur are its location and the use of dielectric grease." | Make sure all the connections are connected, mounting points tightened, and you're done. Our home mechanic says, "My Bussman setup cost me about $15, including the relay, wiring and end connections. I've been very happy with it. I've had no averse weather issues with its 'open' design. The two factors that have helped make that occur are its location and the use of [[Waterproofing your electrical connections|dielectric grease]]." | ||